Standards & Ethics
Standards of Practice are guidelines
for Property Inspectors to follow in the performance
of their inspections. They are the most widely accepted
property inspection guidelines in use, and include all
of the major systems and components found within buildings.
The Standards of Practice and Code of Ethics are recognized
by many government, professional, and legal authorities
and associations as the standard for professional performance
by Registered Home Inspectors (RHI). Each Home
Reference Book comes complete with a copy of the
Canadian and American Standards and Ethics. Below are
the Standards of Practice followed by McKenzie-Taylor
& Associates Ltd.
- Introduction
- Purpose & Scope
- Structural components
- Exterior
- Roofing
- Plumbing
- Electrical
- Heating
- Central Air Conditioning
- Interiors
- Insulation & Ventilation
- Solid fuel burning appliances
- General limitations and exclusions
1. Introduction.
McKenzie-Taylor & Associates
Ltd. are members in good standing of the Ontario Association
of Home Inspectors (OAHI). As such we follow the Standards
of Practice as set out by the OAHI as seen below.
2.
Purpose and Scope.
The purpose of these Standards
of Practice is to establish a minimum and uniform standard
for private, fee-paid home inspectors who are members
of the Ontario Association of Home Inspectors. Home
Inspections performed to these Standards of Practice
are intended to provide the client with information
regarding the condition of the systems and components
of the home as inspected at the time of the Home Inspection.
Inspectors shall inspect:
- Readily accessible systems
and components of homes listed in these Standards
of Practice.
- Installed systems and components
of homes listed in these Standards of Practice.
Inspectors shall report:
- On those systems and components
inspected which, in the professional opinion of
the inspector, are significantly deficient or are
near the end of their service lives.
- A reason why, if not self-evident,
the system or component is significantly deficient
or near the end of its service life.
- The inspector's recommendations
to correct or monitor the reported deficiency.
- On any systems and components
designated for inspection in these Standards of
Practice which were present at the time of the Home
Inspection but were not inspected and a reason they
were not inspected.
These Standards of Practice are
not intended to limit inspectors from:
- Including other inspection
services, systems or components in addition to those
required by these Standards of Practice.
- Specifying repairs, provided
the inspector is appropriately qualified and willing
to do so.
- Excluding systems and components
from the inspection if requested by the client.

3.
Structural Components.
The inspector shall inspect the
structural components including foundation and framing:
- By probing a representative
number of structural components where deterioration
is suspected or where clear indications of possible
deterioration exist. Probing is NOT required when
probing would damage any finished surface or where
no deterioration is visible.
The inspector shall describe:
- The foundation and report
the methods used to inspect the under-floor crawl
space
- The floor structure
- The wall structure
- The ceiling structure
- The roof structure and
report the methods used to inspect the attic.
The inspector is NOT required
to
- Provide any engineering
service or architectural service
- Offer an opinion as to
the adequacy of any structural system or component

4.
Exterior
The inspector shall inspect:
- The exterior wall covering,
flashing and trim.
- All exterior doors.
- Attached decks, balconies,
stoops, steps, porches, and their associated railings.
- The eaves, soffits, and
fascias where accessible from the ground level.
- The vegetation, grading,
surface drainage, and retaining walls on the property
when any of these are likely to adversely affect
the building.
- Walkways, patios, and driveways
leading to dwelling entrances.
- Describe the exterior wall
covering.
The inspector is NOT required
to inspect:
- Screening, shutters, awnings,
and similar seasonal accessories.
- Fences.
- Geological, geotechnical
or hydrological conditions.
- Recreational facilities.
- Outbuildings.
- Seawalls, break-walls, and
docks.
- Erosion control and earth
stabilization measures.

5.
Roofing
The inspector shall inspect:
- The roof covering.
- The roof drainage systems.
- The flashings.
- The skylights, chimneys,
and roof penetrations.
- Describe the roof covering
and report the methods used to inspect the roof.
The inspector is NOT required
to inspect:
- Antennae.
- Interiors of flues or chimneys
which are not readily accessible.
- Other installed accessories.

6.
Plumbing
The inspector shall inspect:
- The interior water supply
and distribution systems including all fixtures
and faucets.
- The drain, waste and vent
systems including all fixtures.
- The water heating equipment.
- The vent systems , flues,
and chimneys.
- The fuel storage and fuel
distribution systems.
- The drainage sumps, sump
pumps, and related piping.
The inspector shall describe:
- The water supply, drain,
waste, and vent piping materials.
- The water heating equipment
including the energy source.
- The location of main water
and main fuel shut-off valves.
The inspector is NOT required
to inspect:
- The clothes washing machine
connections.
- The interiors of flues or
chimneys which are not readily accessible.
- Wells, well pumps, or water
storage related equipment.
- Water conditioning systems.
- Solar water heating systems.
- Fire and lawn sprinkler
systems.
- Private waste disposal
systems.
The inspector shall determine:
- Whether water supply and
waste disposal systems are public or private.
- The quantity or quality
of the water supply.

7.
Electrical
The inspector shall inspect:
- The service drop.
- The service entrance conductors,
cables, and raceways.
- The service equipment and
main disconnects.
- The service grounding.
- The interior components
of service panels and sub panels.
- The conductors.
- The overcurrent protection
devices.
- A representative number
of installed lighting fixtures, switches, and receptacles.
- The ground fault circuit
interrupters.
The inspector shall describe:
- The amperage and voltage
rating of the service.
- The location of main disconnect(s)
and sub panels.
- The wiring methods.
The inspector shall report:
- On the presence of solid
conductor aluminum branch circuit wiring.
- On the absence of smoke
detectors.
The inspector is NOT required
to inspect:
- The remote control devices
unless the device is the only control device.
- The alarm systems and components.
- The low voltage wiring,
systems and components.
- The ancillary wiring, systems
and components not a part of the primary electrical
power distribution system.
- Measure amperage, voltage,
or impedance

8.
Heating
The inspector shall inspect:
- The installed heating equipment.
- The vent systems, flues,
and chimneys.
The inspector shall describe:
- The energy source.
- The heating method by its
distinguishing characteristics.
The inspector is NOT required
to inspect:
- The interiors of flues
or chimneys which are not readily accessible.
- The heat exchanger.
- The humidifier or dehumidifier.
- The electronic air filter.
- The solar space heating
system.
- Determine heat supply adequacy
or distribution balance.

9.
Central Air Conditioning
The inspector shall inspect the
installed central and through-wall cooling equipment.
The inspector shall describe:
- The energy source
- The cooling method by its
distinguishing characteristics.
The inspector is NOT required
to inspect:
- Electronic air filters.
- Determine cooling supply
adequacy or distribution balance.

10.
Interiors
- The inspector shall inspect:
- The walls, ceilings, and
floors.
- The steps, stairways, and
railings.
- The countertops and a representative
number of installed cabinets.
- A representative number
of doors and windows.
- Garage doors and garage
door operators.
The inspector is NOT required
to inspect:
- The paint, wallpaper, and
other finish treatments.
- The carpeting.
- The window treatments.
- The central vacuum systems.
- The household appliances.
- Recreational facilities.

11.
Insulation & Ventilation
The inspector shall inspect:
- The insulation and vapor
retarders in unfinished spaces.
- The ventilation of attics
and foundation areas.
- The mechanical ventilation
systems.
The inspector shall describe:
- The insulation and vapor
retarders in unfinished spaces.
- The absence of insulation
in unfinished spaces at conditioned surfaces.
The inspector is NOT required
to:
- Disturb insulation or vapor
retarders.
- Determine indoor air quality.

12.
Solid Fuel Burning Appliances
The inspector shall inspect:
- The system components.
- The vent systems, flues,
and chimneys.
The inspector shall describe:
- The fireplaces and solid
fuel burning appliances.
- The chimneys.
The Inspector is NOT required
to inspect:
- The interiors of flues
or chimneys.
- The firescreens and doors.
- The seals and gaskets.
- The automatic fuel feed
devices.
- The mantles and fireplace
surrounds.
- The combustion make-up air
devices.
- The heat distribution assists
whether gravity controlled or fan assisted.
- Ignite or extinguish fires.
- Determine draft characteristics.
- Move fireplace inserts or
stoves or firebox contents.

13.
General Limitations and Exclusions
General limitations:
Inspections performed in accordance
with these Standards of Practice:
- Are not technically exhaustive.
- Will not identify concealed
conditions or latent defects.
These Standards of Practice
are applicable to buildings with four or fewer dwelling
units and their garages or carports.
General exclusions:
The inspector is not required
to perform any action or make any determination unless
specifically stated in these Standards of Practice,
except as may be required by lawful authority.
Inspectors are NOT required
to determine:
- The condition of systems
or components which are not readily accessible.
- The remaining life of any
system or component.
- The strength, adequacy,
effectiveness, or efficiency of any system or component.
- The causes of any condition
or deficiency.
- The methods, materials,
or costs of corrections.
- Future conditions including,
but not limited to, failure of systems and components.
- The suitability of the property
for any specialized use.
- Compliance with regulatory
requirements (codes, regulations, laws, ordinances,
etc.).
- The market value of the
property or its marketability.
- The advisability of the
purchase of the property.
- The presence of potentially
hazardous plants or animals including, but not limited
to wood destroying organisms or diseases harmful
to humans.
- The presence of any environmental
hazards including, but not limited to toxins, carcinogens,
noise, and contaminants in soil, water, and air.
- The effectiveness of any
system installed or methods utilized to control
or remove suspected hazardous substances.
- The operating costs of systems
or components.
- The acoustical properties
of any system or component.
Inspectors are NOT required
to offer:
- Or perform any act or service
contrary to law.
- Or perform engineering services.
- Or perform work in any trade
or any professional service other than home inspection.
- Warranties or guarantees
of any kind.
Inspectors are NOT required
to operate:
- Any system or component
which is shut down or otherwise inoperable.
- Any system or component
which does not respond to normal operating controls.
- Shut-off valves.
Inspectors are NOT required
to enter:
- Any area which will, in
the opinion of the inspector, likely be dangerous
to the inspector or other persons or damage the
property or its systems or components.
- The under-floor crawl spaces
or attics which are not readily accessible.
Inspectors are NOT required
to inspect:
- Underground items including,
but not limited to underground storage tanks or
other underground indications of their presence,
whether abandoned or active.
- Systems or components which
are not installed.
- Decorative items.
- Systems or components located
in areas that are not entered in accordance with
these Standards of Practice.
- Detached structures other
than garages and carports.
- Common elements or common
areas in multi-unit housing, such as condominium
properties or cooperative housing.
Inspectors are NOT required
to:
- Perform any procedure or
operation which will, in the opinion of the inspector,
likely be dangerous to the inspector or other persons
or damage the property or it's systems or components.
- Move suspended ceiling tiles,
personal property, furniture, equipment, plants,
soil, snow, ice, or debris.
- Dismantle any system or
component, except as explicitly required by these
Standards of Practice.

Ethics
Honesty, justice
and courtesy form a moral philosophy which, associated
with mutual interest among people constitutes the foundation
of ethics. The members should recognize such a standard,
not in passive observance, but as a set of dynamic principles
guiding their conduct. It is their duty to practice
the profession according to this code of ethics.
As the keystone of professional
conduct is integrity, the members will discharge their
duties with fidelity to the public, their clients, and
with fairness and impartiality to all. They should uphold
the honour and dignity of their profession and avoid
association with any enterprise of questionable charachter,
or apparent conflict of interest.
- The member will express an
opinion only when it is based on practical experience
and honest conviction.
- The member will always act
in good faith toward each client.
- The member will not disclose
any information concerning the results of the inspection
without the approval of the clients or their representatives.
- The member will not accept
compensation, financial or otherwise, from more than
one interested party for the same service without
the consent of all interested parties.
- The member will not accept
nor offer commisions or allowances, directly or indirectly,
from other parties dealing with their client in connection
with work for which the member is responsible.
- The member will promptly disclose
to his client any interest in a business which may
effect the client. The member will not allow any interest
in any to effect the quality or reults of their inspection
work which they may be called upon to perform. The
inspection work may not be used as a vehicle by the
home inspector to deliberately obtain additional work
in another field.
- An inspector shall make
every effort to uphold, maintain and improve the professional
integrity, reputation and practice of the home inspection
industry. He will report all such relevant information,
including violations of this Code by other members,
to the Association for possible remedial action.
Contents
copyright © 2005 Ontario Association of Home Inspectors.
|